Halogenated organic compounds are widely used in chemical industries as solvents, intermediates and products. Most of these products pose a considerable threat to human health as well as to environment.
Therefore, a reliable and sensitive monitory device is needed!
The PAIPOX-Monitor was invented to meet these requirements!
The main application is waste and cooling water monitoring in chemical processes. It even can be used in highly polluted waste waters with a high VOC-load.
Operation principle
Purgeable organic compounds are stripped off the sample and transferred into a stream of demineralized water. In a UV-radiation initialized reaction the organic compounds are decomposed and the resultant halogenic-ions are detected potentiometrically. The initial POX-concentration is calculated using a calibration curve.
Turbidity, colour or pH-value don´t have an influence on the measurement!
Handling
General control, Parameter setting and the visualisation of measurement results, error messages as well as maintenance requests are displayed on 7“-touch panel. All menus are password protected to prevent unauthorized intervention. The screen displays measurement results numerically as well as graphically. For multiple channel instruments the values are displayed for each channel separately.
- Detectable Compounds
- High Reliability
- Communication
- Outputs
- Options
- Maintenance
- Analog outputs
- Specification
- Dichloromethane
- Vinyl Chloride
- Chloroform
- Dichloropropane
- Tetrachloromethane
- Chlorobenzene
- Dichloroethane
- Trichloroethane
- Tetrachloroethane
- Dichloroethene
- Trichloroethene
- etc.
All parts are easily accessible and are replaced in a few minutes. The user himself can do all maintenance work. Down times of the instrument are minimized!
- Multiplexer for up to 8 channels
- Detection of purgeable brominated compounds
- Detection of non-halogenated organic compounds (“VOC”)
- Filtration systems
- Insitu-Stripper
- Profibus
- Modbus
- ATEX
- Audit-Trail
All functions are continuously controlled during operation. Any malfunction will trigger an alarm and a text message is displayed on the screen. Also, all faults are stored in the memory of the instrument.
Critical parameters like UV-lamp live time and the quality of the demi-water are continuously monitored. If maintenance is necessary a text message is displayed and a digital output is triggered (optional). This makes maintenance a lot easier!
All maintenance work can be done by the user himself! No special tools or knowledge is required!
- Method: Potentiometric determination after UV-digestion
- Range: Approx. 0,1 – 1000 ppm
- Interval: Continuous, T90 approx. 5 minutes
- Channels: Max. 8
- Sample: Pressure: No pressure, sampling by integrated pump; Flow: 10 – 20l/h; Temperature: > 0 - 30 °C (higher temperatures with optional sample cooler)
- Detector: Potentiometric 2 electrodes, NDIR (option)
- Alarms: Fault (potential free, NC/NO); Maintenance request (potential free, NC/NO); Threshold (potential free, NC/NO), option
- Status signal: For remote control (potential free, optional)
- Analog outputs: Max 8; (0)4 – 20mA, galvanically separated, max. 500 Ohms
- Digital input: variable, Start/Stop etc. (optional)
- Communication: Ethernet, Profibus (optional), Modbus (optional)
- Environmental cond.: Inhouse mounting; Rel. humidity: 5 – 95% (not condensing); Temperature:
10 – 40 °C - Housing: Standard: Wall mounting, Upper part: steel, powder coated; Lower part: fiber reinforced unsaturated polyester
- ATEX: Stainless steel, fiberglass enforced GFK with PU-foam insulation
- Dimensions: 600x1180x350mm (WxHxD) non ATEX only
- Weight: ±60 kg
- Supply: Mains: 95 - 264V ac, 100 watts; 45 - 65Hz:
Instrument air: Dry, oil free according ISA-S7.0.01-1996 (optional for corrosive atmosphere and atex)
waste: atmospheric open