Skip to content
Akan Industrial and Automation

Multisensor Systems

Multisensor MS1200-S Oil-in-Water Analyzer

Online oil-in-water and VOC analyzer for drinking water intakes, boreholes and process water, detecting hydrocarbons from 1 ppb without touching the water or using reagents.

  • River, reservoir and borehole water intakes
  • Drinking water treatment plant protection
  • RO membrane protection
  • Activated carbon bed breakthrough
  • Process and cooling water
Multisensor MS1200-S Oil-in-Water Analyzer

The Multisensor MS1200-S is an online oil-in-water and VOC analyzer that detects hydrocarbons and volatile organic compounds in water from 1 ppb to 3000 ppb. It is designed as an early warning system for drinking water intakes, boreholes and process water, and it measures without touching the water and without reagents. Akan Industrial and Automation is the Multisensor Systems dealer in Türkiye and supplies, installs and commissions the MS1200-S.

How does the MS1200-S work?

The analyzer uses contactless headspace sensing based on Henry’s law. Water flows continuously through a 316 stainless steel sampling tank. Volatile compounds and water vapour move from the water into the air space above it until they reach equilibrium; a sample of this headspace gas is then passed across an electronic-nose sensor array, and the response is converted into a concentration in ppb.

Measuring principle: volatiles move from the water into the headspace (Fig. 1); headspace air is passed across the sensor and the response is analysed (Fig. 2)

Because only gas reaches the sensor, suspended solids, turbidity and dissolved minerals cannot coat it. This is the main difference from UV, infrared and fluorescence analyzers, whose optics need regular cleaning, and from colorimetric analyzers, which consume reagents.

What can it detect?

The MS1200-S is a broad-band early warning instrument. It responds to:

  • Fuels and oils: diesel, kerosene, gasoline and heating oil
  • Aromatic hydrocarbons, including BTEX (benzene, toluene, ethylbenzene, xylene)
  • Polycyclic aromatic hydrocarbons (PAHs)
  • Aliphatic hydrocarbons
  • Chlorinated solvents such as trichloroethylene, tetrachloroethylene and vinyl chloride

The analyzer is factory calibrated with toluene and reports total VOCs as a toluene equivalent. It can also be calibrated for a specific compound when a known substance must be monitored.

Typical applications

  • Raw water intakes: rivers, reservoirs and boreholes that feed drinking water treatment plants, where a spill can force a plant shutdown or expensive filter replacement
  • RO membrane and activated carbon protection: detecting hydrocarbons before they reach membranes or break through carbon beds
  • Process and cooling water: trace contamination from leaking heat exchangers or pumps
  • Remediation sites: monitoring treated groundwater for residual contamination

For higher concentrations in industrial effluent, see the MS1210-S and MS1220-S; for VOCs in gas streams, the MS4000-S.

Key specifications

Parameter Value
Detection range 1–3000 ppb total VOCs (display range configurable, default 0–1000 ppb)
Repeatability ±2%
Accuracy ±10% from 30 to 3000 ppb (toluene standard)
Measurement Continuous, new reading every 2 seconds
Water temperature 1–50 °C
Ambient temperature 0–50 °C (climate control may be needed)
Sample flow 2 l/min
Outputs 4–20 mA (isolated), 3 relays: alarm 1, alarm 2, fault (5 A)
Communication Modbus optional; Profibus, HART, Foundation Fieldbus on request
Interface and data Touchscreen; data storage on µSD card / PC (6 months)
Enclosure IP65, powder-coated stainless steel; 316 stainless steel sampling tank
Dimensions and weight 650 × 960 × 400 mm, 30 kg
Power supply 90–240 V AC 50/60 Hz or 9–36 V DC; max 45 W, typically 20 W
Maintenance Service every 6 months (filters, restrictor); air pump every 18–36 months

Why choose Akan for the MS1200-S?

Akan engineers the complete installation around the analyzer: sample take-off and return lines, an analyzer cabinet or online analyzer system where needed, alarm integration with SCADA or DCS, commissioning and periodic service. Contact us with your water source and the contaminants you want to detect, and we will recommend the right model and calibration.

Frequently asked questions

What does the MS1200-S oil-in-water analyzer measure?

It measures total volatile organic compounds (VOCs) dissolved in water, including most PAHs, aromatic hydrocarbons such as BTEX, aliphatic hydrocarbons, fuels and chlorinated solvents. The result is reported in ppb as a toluene equivalent.

Does the sensor touch the water?

No. The MS1200-S samples the headspace above the water in its stainless steel sampling tank. Because the sensor never contacts the water, there is no fouling, no sensor cleaning and very low drift.

Does the MS1200-S detect diesel, kerosene and gasoline?

Yes. Fuels such as diesel, kerosene and gasoline release volatile compounds that the analyzer detects, which makes it suitable as an early warning system for fuel spills.

How often does the analyzer need maintenance?

A service every 6 months replaces low-cost consumables such as filters and the restrictor; the air pump is replaced every 18–36 months. No reagents are needed between services.

Which MS12xx model should I choose?

The MS1200-S covers trace levels from 1 to 3000 ppb for raw and drinking water. For industrial effluent and cooling water up to 40 ppm choose the MS1210-S, and for high concentrations up to 200 ppm the MS1220-S.

Request a quote

Tell us about your application and our engineers will get back to you within one business day.